Hantek DSO5102B – Osciloscop digital 2 canale 100 MHz

Osciloscop Digital 2 canale

  • Banda de frecventa 100 MHz
  • Ecran 7 inch, rezolutie 800×480 pixel
  • Inregistrare 1M
  • Trigger mode: edge/pulse width/line selectable video/slop/overtime

The Hantek DSO5102B provides you with superior performance in a compact, affordable design. It’s loaded with standard features including USB connectivity, automated measurements, limit testing, data loading, and context-sensitive measurement that allow this digital storage oscilloscope to help you get more done in less time. No other digital storage oscilloscope offers as much bandwidth and a high sample rate for the price. Hantek provides realtime sampling with oversampling on all channels, all the time accurately capturing signals in its 1M record length internal memory. This feature packed, digital oscilloscope also features a clear, detailed 7″ color TFT display that includes an innovative on screen „Help” system which provides relevant on-screen help at any time simply by pressing the „HELP” button. This feature makes using the Hantek 5102B a snap.

Features

The Hantek DSO5102B Digital Storage Oscilloscope is a 100MHz DSO that provides real-time sample rates up to 1GSa/s and equivalent sample rates up to 25GSa/s. In addition, it’s 1M memory depth allows for better observation of waveform details. The 7 inch color TFT 16 color LCD Display with Windows-style interface and menus provide easy operation. The unit is light enough and small enough to easily be portable and includes a built in FFT function.

The Hantek DSO5000 Series oscilloscopes, including the 5102, cover the bandwidth from 25MHz to 200MHz and provide real-time and equivalent sample rates respectively up to 1GSa/s and 25GSa/s. With 1M of memory on board, you can store and review waveform details.

With intuitive menus, on-board help and easy-to-operate buttons you can access information quickly during measurements. The multifunction knobs and shortcut keys help you save time during use while the Autoset function lets you detect sine and square waves automatically. The Probe Check Wizard guides you through adjusting the probe compensation and setting the probe option attenuation factor. This 100 Mhz Digital Storage Oscilloscope includes 2 passive probes that may be switched between 1:1 & 10:1 input ratios. Also included is a power cord, USB cable and a CD with the manual and software used to interface with a Windows based personal computer.

Model DSO5202B DSO5102B DSO5062B
Acquisition
Sample Rate Real-Time Sample: 1GS/s
Equivalent Sample: 25GS/s
Acquisition Modes
Normal Normal data only
Peak Detect High-frequency and randon glith capture
Average Wavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling AC, DC, GND
Inpits Impendance 1MΩ±2% 20pF±3pF
Probe Attenuation 1X, 10X
Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X
Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation
Category;

CAT III: 150VRMS (1×);
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC
at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less
than 450V. Excursion above 300V should be of less than 100ms duration. RMS
signal level including all DC components removed through AC coupling must be
limited to 300V. If these values are exceeded, damage to the oscilloscope may
occur.
Horizontal
Sample Rate Range 500MS/s–1GS/s
Waveform Interpolation (sin x)/x
Record Length Maximum 1M samples per single-channel;
maximum 512K  samples per
dual-channel (4K,40K optional)
SEC/DIV Range 2ns/div
to 40s/div
Sample Rate and
Delay Time Accuracy
±50ppmat over any ≥1ms time interval)
Position Range 2ns/div
to 8ns/div;

(-8div x s/div) to 20ms;
20ns/div to 80us/div; (-8div x s/div) to 40ms;
200us/div to 40s/div; (-8div x s/div) to 400s
Delta Time Measurement Accuracy
(Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval
+100ppm × reading + 0.6ns);

>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200
Vertical
Vertical Resolution 8-bit resolution, all channel sampled
simultaneously
Offset Range 2mV/div to 20mV/div, ±400mV;  50mV/div to 200mV/div, ±2V
500mV/div to 2V/div, ±40V; 5V/div to 10V/div, ±50V
Bandwidth 200MHz 100MHz 60MHz
Rise Time at BNC( typical) 1.8ns  3.5ns 5.8ns
Math +, -, *, /, FFT
FFT Windows: Hanning, Flatop, Rectamgular,
Bartlett, Blackman;

1024 sample point
Bandwidth Limit 20MHz
Low Frequency Response (-3db) ≤10Hz at BNC
DC Gain Accuracy ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div;
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy,
Average Acquisition Mode
When vertical displacement is zero, and N ≥16:±
(3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;

When vertical displacement is not zero, and N≥16: ± [3% × (reading +
vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings
from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 10V/div
Volts Measurement Repeatability,
Average Acquisition Mode
Delta volts between any two averages of ≥16
waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types Edge,
Video, Pulse, Slope, Over time, Alternative
Trigger Source CH1,
CH2, EXT, EXT/5, AC Line
Trigger Modes Auto,
Normal, Single
Coupling Type DC,
AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
(Edge Trigger Type)
DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to
Full;

DC(EXT):
200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DC(EXT/5):      
1V from DC to 100MHz;1.75V from 100MHz to 200MHz;      
AC: Attenuates signals below 10Hz;
HF Reject: Attenuates signals above 80kHz;
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz;
attenuates signals below 150kHz
Trigger Level Range CH1/CH2:
±8 divisions from center of screen;

EXT: ±1.2V;
EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy is for signals having
rise and fall times ≥20ns
CH1/CH2:
0.2div × volts/div within ±4 divisions from center of screen;

EXT: ± (6% of setting + 40mV);
EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical) Operates
with input signals ≥50Hz
Video Trigger
Video Trigger Type  CH1,
CH2: Peak-to-peak amplitude of 2 divisions;

EXT: 400mV;
EXT/5: 2V
Signal Formats and Field Rates, Video Trigger Type Supports
NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range 100ns
~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode Trigger
when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger Point Equal:
The oscilloscope triggers when the trailing edge of the pulse crosses the
trigger level.

Not Equal: If the pulse is narrower than the specified width, the trigger
point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse
continues longer than the time specified as the Pulse Width.

Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when
a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range 20ns
~ 10s
Slope Trigger
Slope Trigger Mode Trigger
when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger Point Equal:
The oscilloscope triggers when the waveform slope is equal to the set
slope.

Not Equal: The oscilloscope triggers when the waveform slope is not equal
to the set slope.

Less than: The oscilloscope triggers when the waveform slope is less than
the set slope.

Greater than: The oscilloscope triggers when the waveform slope is greater
than the set slope.
Time Range 20ns ~ 10s
Overtime Trigger
Over Time Mode Rising
edge or Falling edge
Time Range 20ns
~ 10s
Alternative Trigger
Trigger on CH1 Internal
Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2 Internal
Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution 6
digits
Accuracy (typical) ±30ppm
(including all frequency reference errors and ±1 count errors)
Frequency Range AC
coupled, from 4Hz minimum to rated bandwidth
Signal Source Pulse
Width or Edge Trigger modes: all available trigger sources

The Frequency Counter measures trigger source at all times, including when
the oscilloscope acquisition pauses due to changes in the run status, or
acquisition of a single shot event has completed.

Pulse Width Trigger mode: The oscilloscope counts pulses of significant
magnitude inside the 1s measurement window that qualify as triggerable
events, such as narrow pulses in a PWM pulse train if set to < mode and
the width is set to a relatively small time.

Edge Trigger mode: The oscilloscope counts all edges of sufficient
magnitude and correct polarity.

Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor Measurement Voltage
difference between cursors:
V
Time difference between cursors: T
Reciprocal of T in
Hertz (1/ΔT)
Auto Measuerment Frequency,
Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time,
+Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase,
Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot,
RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
Display
Display Type 7
inch 64K color TFT (diagonal liquid crystal)
Display Resolution 800
horizontal by 480 vertical pixels
Display Contrast Adjustable
(16 gears) with the progress bar
Probe Compensator Output
Output Voltage( typical) About
5Vpp into ≥1MΩ load
Frequency(typical) 1kHz
Power Supply
Supply Voltage 100-120VACRMS(±10%),
45Hz to 440Hz, CAT

120-240VACRMS(±10%), 45Hz to 66Hz, CAT
Power Consumption <30W
Fuse 2A, T
rating, 250V
Environmental
Temperature Operating:
32
to 122 (0 to 50);
Nonoperating: -40 to
159.8
(-40 to +71)
Cooling Method Convection
Humidity +104 or below (+40 or below): ≤90% relative
humidity;

106 to 122 (+41 to 50):
≤60% relative humidity
Altitude Operating:
Below 3,000m (10,000 feet);

Nonoperaring: Below 15,000m(50,000 feet)
Mechanical
Size Length
385mm, Width 200mm, Height 245mm
Weight 3.5KG(with
Packing);  2.08KG(without Packing
Banda de frecventa

100 MHz

Brand

Hantek